A&D MF-50 Moisture Analyzer

N ew from A&D - The MF-50 Moisture Analyzer offering the latest in weighing technology implementing the Super Hybrid Sensor with moisture balance features that outshine the competition. Choose from three affordably priced models, designed to streamline the process of product moisture analysis. Additional uses include moisture analysis in the environmental, chemical, pharmaceutical industries, and more.

The innovative Heat Chamber houses a 400 Watt Halogen heating lamp producing fast and accurate results aided by its uniquely designed SRA (Secondary Radiation Assist) Filter , which serves to radiate heat uniformly, protect the lamp from splatter during testing and provide a Progress Monitoring Translucent Glass Window. The SRA filter is easy to clean ensuring optimum performance while the halogen lamp is user replaceable. This of course will save time and money and minimize down time and labor costs.

The Vacuum Fluorescent Display allows the results to be clearly displayed even in areas with poor lighting. The large keypads and intuitive embedded software makes the A&D MS/MX/MF moisture balance a breeze to use walking you through the convenient test setup parameters.

Attention to the placement of handles make the unit safe to use minimizing burn related mishaps.

Add it all up and A&D is Clearly a Better Value over all the other moisture balances on the market today!

Sodium Tartrate Dihydrate is included for verifying the performance any of the A&D moisture analyzers. Sodium Tartrate Dihydrate is a chemical used in the industry as a standard since it contains 15.66% of a chemically uniform moisture. However, depending on the state of the preservation of the material the moisture of 0.09% or less adheres to the surface of it.

Checking the performance of the moisture balance is simple. Preheat the unit for about eight minutes at 160°C, then put about 5 grams of Sodium Tartrate Dihydrate in the moisture balance. The moisture content rate of 15.50 - 16.00% is obtained in a typical measurement.

 
All A&D Moisture Analyzers come with data acquisition software for exporting data to a computer via the RS-232 interface. The MF-50 comes standard with the WinCT balance communication software for exporting weighing result to a MS Word or Excel. Win CT Moisture exclusive Optimum Temperature Search (OTS) program is designed to display a graph of the moisture content rate change while measuring and makes it easier to set an appropriate analyzing mode setting with a connected PC. Users no longer have to go through a tedious trial and error process to determine optimum temperature and time for quick accurate analysis. Typically it takes days of trial and error to find optimal sample parameters. In just one 30-minute sample run, OTS automatically recommends the ideal time and temperature for a sample type. Because the OTS program helps the user distinguish between desired drying of moisture vs. the undesirable burning of the sample, OTS ensures quick accurate readings every time. In addition to OTS, WinCT-Moisture provides bidirectional data collection, graph time vs. moisture % and overlays multiple test graphs in different colors to visually compare results. Data can be exported to ExcelT or sent as an email attachment. All A&D moisture analyzers measure moisture thermogravimetrically. Thermogravimetric moisture analysis is based on the principles of vaporization of water during the during process. The moisture balances monitors the weight loss of a sample as the material is heated. The sample weight prior to heating and after reaching a steady-state mass after drying determines the moisture content. The halogen bulb produces the heating of the sample by infrared radiation. The thermogravimetric method offers advantages over moisture determination using a chemical method such as Karl Fisher Titration. Thermogravimetric moisture analysis is simple to perform and adaptable to many conditions verses Karl Fisher Titration can be subjective, and require the handling and disposal of solvents and potentially hazardous materials.

A&D technology increases your productivity

  • Fast heat to 200°C in only 2 minutes
  • Uniform heating drastically improved by SRA technology
  • SRA filter stops contamination from spatter of the test sample
  • Removable SRA filter makes for easy cleaning
  • User replaceable Halogen lamp cuts cost and down time
  • GLP compliant format when printed results are required

A&D know-how gives superior analytical performance

  • Repeatability of 0.01% (S.D.) in moisture determination
  • High accuracy gives value of Sodium Tartrate Dihydrate at 15.66% (+0.3/-0.1)
  • 50 gram capacity by 1mg readability (MX-50 readability to 1mg while MF-50 is 2mg)
  • Programmable Heating Mode Memory
  • Easy to read Vacuum Fluorescent Display
  • Standard RS232 port for connection to computer or optional printer .
Progress window for heating check Heating process can be checked through translucent window Easy handling of the unit Ergonomically designed pan handle eliminates mishaps such burns when moving a hot sample tray into or out of the unit from either side.

Display Mode give you the choice of % moisture, % solids, weight, atro moisture or atro solids

ATRO Moisture content refers to a measurement of moisture content as compared to dry weight. Typically moisture content = (wet weight - dry weight)/wet wgt * 100% ATRO wet weight = (wet wgt-dry wgt)/dry weight * 100%

So for a 100 gram sample drying to 75 grams. Wet Moisture content is 25/100=25% However ATRO moisture content is 25/75= 33.3%

Similar idea for Dry content vs. ATRO dry content. Dry content = dry wgt/wet wgt ATRO dry content = wet wgt/ dry wgt

Key Switch Operation
Selection of measurement condition which has been registered. Example: Standard Mode/Automatic Complete Mode/Timer Mode/Manual Mode/Any custom measurement condition operator has stored in memory.
Selection of measurement condition. Example: Standard Mode > Automatic Complete Mode > etc. The "Select" key to select a measurement condition you want to change. For example, press the "Select" key until temperature is highlight and then use the "up/down" arrow key pad to select the desired temperature.
Change in measurement condition. These keys allow you to scroll through programs. Example: Standard Mode > Automatic Complete Mode > etc. Also used to change the settings for temperature, measurement time, complete condition, sample set when storing a custom measurement condition (MX-50 has memory for 20 measurement programs while the MF-50 offers storage for only 10 measurement programs.
Registration of measurement condition
Start measurement
Stop measurement
Pushing the reset button places the weight display at zero. Place the sample pan on the support plate and close heater cover to eliminate air turbulence. Press the '"Reset" key to zero out / tare the weight of the moisture pan. Once the display shows 0.000 g, open the cover and place sample on moisture pan.

The MF moisture balance comes with powerful software for ease of operation, program storage and user customization . Four measurement complete conditions are preprogrammed and are adaptable to various measuring methods. In addition, in each measurement complete condition, measurement accuracy, time and unit can be set to your desired selection and recalled saving you time . the MF-50 for 10 sets . Suitable sets of the conditions can be individually called according to the sample. Whether your determining moisture% for primary or secondary sludge in a wastewater environment, or testing lab to determine dry content % for the food industry for dry milk or grain, it's simply to select and run the test once you program and store the test setup parameters.

TEST WITH THE BEST
Progress window for heating check Heating process can be checked through translucent window.
Easy handling of the unit Ergonomically designed pan handle eliminates mishaps such burns when moving a hot sample tray into or out of the unit from either side. Wing handle for easy opening and closing of the heater cover.
SRA technology Straight halogen lamp and uniquely designed SRA (Secondary Radiation Assist) filter gives shorter measurement time, thanks to the fast and uniform heating.
Quick reference A convenient operating guide installed at the bottom of the analyzer.

 
A&D MF-50 Moisture Analyzer Specifications
Measurement Method 400 W straight halogen lamp heating system with SRA filter & SHS Weighing technology
Max Sample Weight Capacity 51 g
Weight Resolution 0.002 g
Moisture Content Display 0.05/0.1/1%
Moisture Content Accuracy over 1 g: 0.20% over 5 g: 0.05%
Heating Technology Halogen lamp (Straight type, 400 W max, 5000 hours)
Heating Time The heating time can be set in the range of 1 to 480 minutes, and increments between 1-60 minutes in 1 minute intervals, 60 - 480 minutes in 5 minute increments.
Drying Temperature 50 - 200°C (1°C increment)
Memory of Measurement Programs 10 sets
Measurement Programs Standard Mode/Automatic Complete Mode/Timer Mode/Manual Mode
Measurement Mode Wet base/Dry base/Solid content/Ratio
Display Type Large VFD
Interface RS-232C Standard
Operating Temperature 5-40°C(41-104°F)less than 85% RH
GLP/GMP/ISO Available
Self Check Function Standard
Communication Software Win CT standard
Sample Pan Size ø 85 mm / 3.4 inches
Power AC 200V-240V (1.5 A) 50/60 Hz with 400W Lamp
Physical Dimensions 215 (W) x 320 (D) x 173(H) mm 8.5" x 12.6" x 6.8"
Weight Approx. 6 kg / 13.2 lbs
Standard Accessories 20 Sample Pans, 2 Pan Handles, Tweezers, Spoon, Test Sample (30g of Sodium Tartrate Dihydrate),  Display Cover, Dust Cover, Instruction Manual, Quick Reference Card, Power cable, 2 Fuses

 now You need Adobe Acrobat Reader to view. The instruction manual contains detailed information regarding the moisture balance. It outlines the operation, additional features, keypad functions and standard accessories that come with the awesome moisture balance. Reviewing the manual will answer all your questions and help you in your final selection.

              

MPN A&D MF-50 Moisture Analyzer
Brand A&D Weighing
Model MF-50 Moisture Analyzer
  • Condition: New
  • MPN: A&D MF-50 Moisture Analyzer
  • Brand: A&D Weighing
  • Model: MF-50 Moisture Analyzer

PicClick Insights - NEW A&D MF-50 Moisture Analyzer w/ A&D Warranty, 200-240 Volts PicClick Exclusive

  •  Popularity - 0 watchers, 0.0 new watchers per day, 129 days for sale on eBay. 0 sold, 1 available.
  •  Best Price -
  •  Seller - 1,834+ items sold. 0% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive