Eight-way Output Programmable Multichannel Industrial Time Relay/KRPT72 Cyclic.

EUR 74,55 Buy It Now or Best Offer 18d 15h, FREE Shipping, 60-Day Returns, Pay with PayPal and you're fully protected.

Seller: Top-Rated Seller saida*technology (3.732) 98.7%, Location: 深圳, Ships to: Worldwide, Item: 254351532357 1PC Eight-way Output Programmable Multichannel Industrial Time Relay/KRPT72 Cyclic This programmable industrial time timer has the advantages of simple setup, novel design, precise time and strong anti-jamming ability, which is not comparable to ordinary timers. At the same time, it has multi-channel control output, each channel can be delayed, and can work independently. Each channel has its own time base starting point to choose. The number of times of work can be set between 0 - 9999, and 0 is an infinite cycle. Multiplex combined operation can work sequentially, simultaneously, alternately and circularly. Built-in general cycle function program, you can cycle at any time point (the number of cycles can be set). With monitoring function, it can display the current working status or number of times of each route. Multiplex control output combined operation can completely replace part of the PLC function, achieve the goal of cost saving and automation. There are four working modes for each route: 0 mode: Delayed disconnection: After starting, the relay immediately sucks in, and the relay is disconnected and terminated after the time of delay T1 arrives. T1 time can be set between 0.01 seconds and 9999 hours. 1 mode: Delayed suction: After power-on, the relay does not suck at first. After starting, the relay sucks after the delay time T1 arrives and ends. T1 time can be set between 0.01 seconds and 9999 hours. 2 mode: After starting, the relay immediately sucks, delays T1 time to arrive before the relay disconnects, and then delays T2 time to arrive after the end. The number of cycles can be set between 0 and 9999, and 0 is an infinite cycle. T1 time and T2 time can be set between 0.01 seconds and 9999 hours. 3 mode: Delayed suction and delayed disconnection: after power-on, the relay does not suck at first. After starting and delayed T1 time arrives, the relay does not suck. After delayed T2 time arrives, the relay disconnects. The number of cycles can be set between 0 and 9999, and 0 is an infinite cycle. T1 time and T2 time can be set between 0.01 seconds and 9999 hours. Note: T1 indicates the first period and T2 indicates the second period. Start mode 1: The controller can be set to start on power (the controller will start work immediately when it is electrified) 2: It can be set that the reset should be triggered by a click to start the controller. Each route can choose the starting point of operation: Route 1: Start to enter the timing state. Route 2: 1. It can enter the timing state at the start of start-up. (2) It can start to enter the timing state only after the first timing of the 1st route T1 or T2. (3) It can enter the timing state only after the completion of the first route work. Route 3: 1. It can enter the timing state at the start of start-up. (2) It can enter the timing state only after the first timing of the first T1 or T2. (3) It can enter the timing state only after the completion of the first route work. (4) It can not enter the timing state until the end of the second T1 or T2 timing. (5) It can enter the timing state only after the completion of the second route work. Route 4: 1. It can enter the human timing state at the start. (2) It can enter the timing state only after the first timing of the first T1 or T2. (3) It can enter the timing state only after the completion of the first route work. (4) It can not enter the timing state until the end of the second T1 or T2 timing. (5) It can enter the timing state only after the completion of the second route work. It can enter the timing state only after the first timing of route 3 T1 or T2 is completed. It can enter the timing state only after the completion of the third route work. Route 5: 1. It can enter the human timing state at the start of start-up. (2) It can enter the timing state only after the first timing of the first T1 or T2. (3) It can enter the timing state only after the completion of the first route work. (4) It can not enter the timing state until the end of the second T1 or T2 timing. (5) It can enter the timing state only after the completion of the second route work. It can enter the timing state only after the end of the first timing of route 3 T1 or T2. It can enter the timing state only after the completion of the third route work. The timing state can start after the first timing of the 4th route T1 or T2. It can start to enter the timing state only after the completion of the fourth route work. Route 6: 1. It can enter the human timing state at the start. (2) It can enter the timing state only after the first timing of the first T1 or T2. (3) It can enter the timing state only after the completion of the first route work. (4) It can not enter the timing state until the end of the second T1 or T2 timing. (5) It can enter the timing state only after the completion of the second route work. It can enter the timing state only after the end of the first timing of route 3 T1 or T2. It can enter the timing state only after the completion of the third route work. The timing state can start after the first timing of the 4th route T1 or T2. It can start to enter the timing state only after the completion of the fourth route work. It can start to enter the timing state after the first timing of the 5th route T1 or T2. The timer can be started only after the completion of Route 5 work. Route 7: 1. It can enter the human timing state at the start. (2) It can enter the timing state only after the first timing of the first T1 or T2. (3) It can enter the timing state only after the completion of the first route work. (4) It can not enter the timing state until the end of the second T1 or T2 timing. (5) It can enter the timing state only after the completion of the second route work. It can enter the timing state only after the end of the first timing of route 3 T1 or T2. It can enter the timing state only after the completion of the third route work. The timing state can start after the first timing of the 4th route T1 or T2. It can start to enter the timing state only after the completion of the fourth route work. It can start to enter the timing state after the first timing of the 5th route T1 or T2. The timer can be started only after the completion of Route 5 work. The timing state can be started after the first timing of Route 6 T1 or T2. (5) The timing can be started only after the completion of Route 6 work. Route 8: 1. It can enter the human timing state at the start. (2) It can enter the timing state only after the first timing of the first T1 or T2. (3) It can enter the timing state only after the completion of the first route work. (4) It can enter the timing state only after the first timing of Route 2 T1 or T2. (5) It can enter the timing state only after the completion of the second route work. It can enter the timing state only after the first timing of route 3 T1 or T2 is completed. It can enter the timing state only after the completion of the third route work. The timing state can start after the first timing of the 4th route T1 or T2. It can start to enter the timing state only after the completion of the fourth route work. It can start to enter the timing state after the first timing of the 5th route T1 or T2. The timer can be started only after the completion of Route 5 work. The timing state can be started after the first timing of Route 6 T1 or T2. (5) The timing can be started only after the completion of Route 6 work. The timing state can start after the first timing of the 7th route T1 or T2. The timing can be started only after the completion of the work on Route 7. Total cycle: After the program is finished, it starts from scratch. The interval can be set. The reset cycle can be performed at any time point (the starting point is optional). The number of cycles can be set between 0 and 9999, and 0 is no cycle. The wiring diagram is as follows: (a common end input, eight points output) 1.warranty period 120day 2.package included:1pc On 06-Sep-19 at 04:37:07 BST, seller added the following information: Condition: New, Brand: Kai Rui, MPN: KRPT72, Model: KRPT72-7J-A

PicClick Insights PicClick Exclusive
  •  Popularity - 150 views, 1.1 views per day, 135 days on eBay. Very high amount of views. 0 sold, 2 available.
  •  Price -
  •  Seller - 3.732+ items sold. 1.3% negative feedback. Top-Rated Seller! Ships on time with tracking, 0 problems with past sales.
Similar Items