SPECIFICATION:
Certifications: CMC. |
household appliances. |
Weight: 15 once (less than 1 LB). |
Battery life: Alkaline: 500 hours. |
Operating altitude: 0 to 2000 meters. |
Battery type: 2 X AA, NEDA 15A, IEC LR6. |
Display: Digital: 4000 count updates 3/sec. |
Size (H*W*L): 7 " * 3.5" * 2" (with holster). |
branch circuits, and lighting systems in large buildings. |
Maximum voltage between any terminal and earth ground: 1000 V. |
Temperature coefficient: 0.1 X (specified accuracy)/ °C (28 °C). |
Fuse protection for A input: 11 A, 1000 V FAST, min. interrupt rating 20,000 A. |
Relative humidity, 40 MΩ Range: 80% from 10 °C to 30 °C; 70% from 30 °C to 40 °C. |
Fuse protection for mA μA inputs: 500 mA, 1000 V FAST, min. interrupt rating 20,000 A. |
CAT I: From high-voltage low-energy sources, e.g., electronic circuits or a copy machine. |
Relative humidity: non-condensing < 10 °C; 90% from 10 °C to 30 °C; 75% from 30 °C to 40 °C. |
Rated transient overvoltage: 4 KV (1.2 x 50 μs) Peak for measurement Categories I, II, and III. |
Temperature: operating: 0 °C to 40 °C; storage: -30 °C to 60 °C indefinitely (to -40 °C for 100 hours). |
CAT III: From equipment in fixed equipment installations, e.g., installation panels, feeders and short. |
CAT II: From equipment supplied from the fixed installation, e.g., Televisions, PCs, portable tools and. |
Safety Compliance: IEC 61010-1, 2000 CAT I 1000 V, CAT II 600 V, and CAT III 300 V over voltage standards. |
Electromagnetic compatibility: complies with FCC part 15, class B, IEC 61326, 3 V/m, performance criterion B. |
Over-voltage installation categories per IEC 61010-1, 2000: the meter is designed to protect against transients in these categories. |
|
ACCURACY SPECIFICATION:
specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). |
Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy. |
|
Function
|
Range
|
Resolution
|
Accuracy |
Model 15B
|
Model 17B |
AC Volts (40 to 500 Hz) v
| 400.0 mV 1
| 0.1 mV
|
3.0 % + 3
| 3.0 % + 3 |
4.000 V 40.00 V 400.0 V 1000 V
| 0.001 V 0.01 V 0.1 V 1 V
|
1.0 % + 3
| 1.0 % + 3 |
DC Millivolts M
| 400.0 mV
| 0.1 mV
|
1.0 % + 10
| 1.0 % + 10 |
DC Volts V
| 4.000 V 40.00 V 400.0 V 1000 V
| 0.001 V 0.01 V 0.1 V 1 V
|
0.5 % + 3
| 0.5 % + 3 |
Diode Test
| 1.000 V
| 0.001 V
| 10 % |
Temperature 3 °C (K-type thermocouple)
| 50 °C to 400 °C 0 °C to 50 °C -55 °C to 0 °C
| 0.1 °C
| NA
| 2 % + 1 °C ± 2 °C 9 % + 2 °C |
Resistance (Ohms)
| 400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ
| 0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ
| 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3
| 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
Capacitance 4 c
| 50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF
| 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF
| 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5
| 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency Hz (10 Hz -100 kHz)
| 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz
| 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz
| NA
| 0.1 % + 3 |
Duty Cycle
| 0.1 % to 99.9 %
| 0.1%
| NA
|
1% typical 5 |
1. Manual and Auto Range.
2. Diode test open circuit test voltage is 1.1 V to 1.6 V and short circuit current is < 0.6 mA (typical).
3. Temperature
specifications do not include thermocouple errors. After inserting the
thermocouple plug into the meter, allow several minutes for thermal
stabilization.
4. Specifications do not
include errors due to test lead capacitance and capacitance floor (may
be up to 1.5 nF in the 50 nF range). For the 17B, errors can be reduced
by using the relative feature.
5. For values between 10% and 90% duty cycle at 50 Hz.
6. When in the 4A range, display will show 4000 counts, please ignore the last digit. |
|
Function
|
Range
|
Resolution
|
Accuracy |
Model 15B
|
Model 17B |
AC Current (40 to 200 Hz)
| 400.0 µA
| 0.1 µA
|
1.5 % + 3
|
1.5 % + 3 |
| 4000 µA
| 1 µA
|
| |
AC Current (40 to 200 Hz)
| 40.00 mA
| 0.01 mA
|
1.5 % + 3
|
1.5 % + 3 |
| 400.0 mA
| 0.1 mA
|
| |
AC Current (40 to 200 Hz)
| 4.000 A6 10.00 A
| 0.01 A 0.01 A
|
1.5 % + 3
|
1.5 % + 3 |
DC Current
| 400.0 µA
| 0.1 µA
|
1.5 % + 3
|
1.5 % + 3 |
| 4000 µA
| 1 µA
|
| |
DC Current
| 40.00 mA
| 0.01 mA
|
1.5 % + 3
|
1.5 % + 3 |
| 400.0 mA
| 0.1 mA
|
| |
|
|
|
| |
DC Current
| 4.000 A6
| 0.01 A
|
1.5 % + 3
|
1.5 % + 3 |
| 10.00 A
| 0.01 A
|
| |
|
|
Function
| Overload Protection
|
Input Impedance (Nominal)
| Common Mode Rejection Ratio
|
Normal Mode Rejection |
AC Volts V
| 1000 V
|
>10 MΩ <100 pF
| >60 dB at dc, 50 or 60 Hz
| _ |
DC Volts V
| 1000 V
|
>10 MΩ <100 pF
| >100 dB at dc, 50 or 60 Hz
| >45 dB at 50 or 60 Hz |
106 V Hz Max
|
|
|
| |
|
STANDARD ACCESSORIES:
A Pair of Original Test leads. |
Thermocouple. |
True FLUKE F17B+ meter. |
Original User Manual. |
|
Notice:    
The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support!.   
|