100mkOhm-1000KOhm 0.1% P4833 Bridge impedance meter resistance standard box

Unsold See similar items £234.70 Buy It Now or Best Offer, £92.67 Shipping, eBay Money Back Guarantee
Seller: electro-radio-device ✉️ (485) 100%, Location: Lviv, Europe, UA, Ships to: WORLDWIDE & many other countries, Item: 332160896787 100mkOhm-1000KOhm 0.1% P4833 Bridge impedance meter resistance standard box. P4833Multifunctional, Multivalued  decade resistance box, bridge, resistor, potentiometer analog of:  General Radio (GenRad), LEEDS & NORTHRUP, ESI, IET Labs, GR, Yokogawa, Shallcross, Tinsley & Co, Shallcross, Leeds & Northrup, L&N, Extech, EMCO, AEMC devices, but has the same or better characteristics:

Characteristics

Value

DC Bridge

Accuracy class

0,1

resistance  measurement  range, Ohm

from 10-4 to 106

DC  Potentiometer

Accuracy class

0,05

Voltage measurement  range, mV

from 0  to  111,10

circuit 1                                 

 

10 decades with 10 mV 10 decades with 1 mV

circuit 2

10 decades with 0,1 mV  10 decades with 0,01 mV

Resistance Box

Accuracy class

0,02 / 1,5x10-4

Resistance indication range, Ohm

from (<0,015) to 1111,10

Minimum decade, Ohm

0,01

 ​​Decade  Value, Ohm

100; 10; 1; 0,1; 0,01 1

  • Dimensions: 250x390x190mm;
  • Weight: kg.

     

Condition: 1.  used, from an old stock, has some scratches on the body;  2.  not tested; working condition is unknown ; 3.  Usually I send unit in  5-10 business days  after receiving payment – this time I need for unit testing procedure and preparing reliable packaging.

This device was also used in USSR and Russia army. So it has best quality , longevity and permanence characteristic.

If necessary, we can provide calibration certificate from Government standardization institute  (+145-265usd).

  Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.  Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons. 

Please take a look on my other items!

If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.  

Device Р4833 is designed to measure resistance, constant e.m.f. , voltage and calibration of thermotechnical devices.

Measuring range: bridge - from 10-4 Ohm to 106 Ohm , potentiometer - from 0 to 111.10 mV , resistance box from initial (≤ 0.015 Ohm) to 1111.10 Ohm . Accuracy class: DC box 0.1 ; DC potentiometer 0.05 ; ; resistance box 0.02 / 1.5 • 10-4

 

Devices Р4833

Device P4833 multimeter (hereinafter - device ) is designed to measure resistance, constant e.m.f. , voltage and calibration of thermotechnical devices.      Devices P4833 working conditions : ambient temperature from 10 ° to 35 ° C, relative humidity 80% at 25 ° C, atmosphere pressure ( 84-106.7) kPa [( 630-800) mmHg ].

 

Technical characteristics

Devices P4833 accuracy class, when used as : dc bridge 0.1 ; dc potentiometer 0.05; resistance box 0.02/1.5•10-4 .

Range: resistance measurements, when using device as bridge from 10-4 to 106 Ohm ;      measuring e.m.f and voltage , when using device P4833 as potentiometer from 0 to 111.10 mV (contour I -10 decades at 10 mV and 10 decades at 1 mV ; contour II -10 decades at 0.1mV , and 10 decades mV at 0.01 mV) ; resistance readings when using device as five -decade resistance box from initial (≤ 0.015 Ohm ) to 1111.10 Ohm ( decade 100 ; 10; 1 ; 0.1; 0.01 Ohm).

 

Table 1

Measured resistance, Ohm

Backs ratio, N

Voltage supply, V

Additional resistanceof external batteries , Ohm

External

Internal

circuits

10-4-10-3

10-4

-

-

1.5

-

10-3-10-2

10-4

-

-

1.5

-

10-2-10-1

10-3

1.5

1.5

1.5

3

10-1-1

10-2

1.5

1.5

1.5

3

1-5

10-2

1.5

1.5

1.5

3

5-102

10-1

1.5

1.5

1.5

3

102-103

1

7

7

36

-

103-104

10

7

7

36

-

104-105

102

48

7

36

510

105-106

103

48

7

36

510

Measuring resistance, Ohm

Measurement error ,%, not more than

Parameters of external galvanometer

Internal galvanometer ( IG)

External galvanometer (EG) - any power supply

Internal battery (IB)

Bridges battery external (BB )

circuits

10-4-10-3

-

±5.0

-

±0.5*

Rr≤20 Ом

10-3-10-2

-

±1.0

±2.0

±0.5*

Ci≤ 1· 10-7 А/div

10-2-10-1

±0.5

±0.5

±0.5

±0.1*

Ci≤ 5· 10-7 А/div

10-1-1

±0.2*

±0.2*

±0.2*

±0.1*

Rr≤20 Ом

1-5

±0.1

±0.1

±0.1

±0.1

 

5-102

±0.1

±0.1

±0.1

±0.1

 

102-103

±0.1

±0.1

±0.1

±0.1

 

103-104

±0.1

±0.1

±0.1

±0.1

 

104-105

±1.0

±0.5

±0.5

±0.1

Ci≤2 · 10-8 А/div

105-106

-

±2.0

±5.0

±0.1

Rr≤20 Ом

 

Note . When measuring resistances in range (10-4-10-3)Ohm ; (10-3-10-2) Ohm external current power supply should be 3A. Significance of back comparison initial resistance should be considered.

    Basic error : 1) When using device P4833 as bridge, the acceptable basic error limit (Δ) in Ohm corresponds to value defined by formulas:

    ∆ = ±10-2 · С · (10-1Rn + X)(1)

   or

    ∆= ±10-2 ·С · X, (2)

where C - accuracy class value, specified for given range ( Table 1); Rn - normalizing resistance value for given measurement range , Ohm (Table 1 ); X - reading , measured from decades switches limbs , Ohm .

     Acceptable basic error limit corresponds to values specified in Table 1, under normal using conditions: ambient temperature (20 ± 5) ° C; relative humidity of 25 to 80% ; atmosphere pressure (84 - 106.7 ) kPa [( 630-800) mm Hg ]; working position - horizontal ; 2) When using device P4833 as potentiometer for emf and voltage acceptable basic error limit measurements (ΔU) in V corresponds to values defined by formula:

∆U= ±5 · 10-4 · (Un/10 + U),(3)

where Un - normalizing value ,V ( Un = 0.1 V); U- potentiometer reading, V, under normal using conditions: ambient temperature (20 ± 2) ° C; relative humidity of 25 to 80%; atmosphere pressure ( 84-106.7 ) kPa [( 630-800) mm Hg ]; working position - horizontal ; no external magnetic field , except the earth one.

     When using device P4833 as potentiometer it must meet requirements of  basic error ( instability) limits in accordance with accuracy class during one year from the date of first certification ( calibration) under normal conditions (above) and under normal conditions of use , transportation and storage. 3) Acceptable deviation limit of actual resistance value (δ) in percentage from nominal when using device as resistance box corresponds to value defined by formula:     δ = ± [0.02+1.5 • 10-4 (Rk/R-1)], (4)

where  Rk - maximum resistance value, Ohm ( Rk = 1111.10 Ohm ); R- nominal resistance value , Ohm.

Actual resistance value deviation from nominal in primary calibration ( at manufacturer release ) and acceptable resistance change δ in percentage per year ( instability) does not exceed value determined by formula (4) under normal using conditions: ambient temperature (20 ± 2) ° C; relative humidity of 25 to 80%; atmosphere pressure ( 84-106.7 ) kPa [( 630-800) mm Hg. ]; working position - any ; steady-state thermal equilibrium and power dissipation are not above nominal .

Acceptable basic error of backs resistances ratio  is not more than  ± 0.025% (except the level with nominal value 0.09864 Ohm, for which acceptable error is not more than ± 0.25%) in normal using conditions (above).

Acceptable basic error of resistors box 2.5 and 7.5 Ohm is not more than ± 0.1%.

Built-in p4833 multimeter device regulated voltage source IPH ("mV") at voltage supply at least 1.3 V and load resistance not less than 25 Ohm provided at clamps

«-X», «mV »  voltage from minus 5V to plus 100 mV.

Voltage regulation discreteness is not more than 0.05% from maximum voltage at clamps «-X», «mV ».

DC Bridge  built into device p4833 is regulated power source IPH ("V") at voltage supply at least 5.6 V provides voltage from 0.5 to 5V at clamps «-X», «B » .

Comparison resistor s acceptable basic error in circuit with measuring connecting lines resistance for automatic bridges and ratio-meter is not more than ± 0.02%.     Primary devices voltage U0 when used as potentiometer is 2.4·10-6V, resolution ΔUn is not more than 25·10-6V. Scale interval of smallest decade on one stage Umin= 10-5V.

Potentiometers installation resistance regulated part provides changes in installation steps, which do not exceed 0.01% from emf normal element value ( 1.0184-1.0194) V.

Primery resistance average value R0 of comparison devices back , resistance during installation of all decadal switches on zero, is not more than 0.015 Ohm.

Primary resistance variation ΔR0 of comparison back, caused by changes in contact resistance  switching devices , is not more than 0.0015 Ohm.

Nominal power dissipation on one decade  is not more than : 0.001 Watt for 0.01 Ohm , 0.01 Watt for 0.1 Ohm , 0.05 Watt  for1 Ohm  and above.

Maximum power dissipation by one decade  is not more than : 0.005 Watt for 0.01 Ohm , 0.05 Watt for 0.1 Ohm , 0.1 Watt for 1 Ohm and higher.

Additional error .

When using device р4833 as bridge additional error limit in working temperature ranges does not exceed maximum acceptable basic error when ambient temperature changes for every 10 ° C.

When using device as potentiometer changes in readings , shown in percentage from  basic error does not exceed 100% when ambient temperature changes for every 10 ° C in range of working temperatures. Note . Additional error caused by operating current installation is  not specified , because it is in  basic error.

When using device as resistance box additional error limit in working temperature range of 15 to 25 ° C, caused by changes in ambient temperature ( environment) between upper (lower) limit of normal temperature conditions range 22 ° C (18 ° C) and some point in related working conditions temperature range 25 ° C (15 ° C), corresponds to the largest change in resistance Rmax, within working temperature from 10 to 15 ° C and 25 ° to 35 ° C for every 5 ° C of temperature change  do not exceed value determined by  formula (4).

When using device p4833 as resistance box additional error limit as a percentage of its nominal value when power dissipation change from normal to any value do not exceed maximum power under normal using conditions and steady-state thermal equilibrium do not exceed value determined by the formula (4).

   

Power supply .

When used as a bridge - from built-in galvanic elements with voltage at least 1.5 mV (with four clamping connection of measured resistance from 10-4 to 102 Ohm), with voltage not less than 7.0 V (with two clamping connection of measured resistances from 102 to 106   of permissible DC pulsation, power supplies from 0 to 0.1%, maximum power consumed do not exceed 3A and 0.05 A; from external power supply according to table 1; from AC voltage ( 220 ± 22)V , frequency (50 ± 0.5) or (60 ± 0.6) Hz, sinusoidal waveform , the higher harmonics coefficient is not more than 5 %.

When used as potentiometer - from built-in and external sources of DC voltage from 1.20 V to 1.65 V.

Power IPH (" mV") - from built-in and external dc sources with voltage from 1.20 to 1.65 V.      Power IPH ("V") - from built-in and external dc sources with voltage from 4.8 to 6.6 V. Acceptable dc pulsation source from 0 to 0.7%, maximum power consumption is not more than 0.025 A.

Power consumed by device bridge p4833 does not exceed 10VA . Devices operating mode time does not exceed 15 minutes, after turn on. Working mode - intermittent .

Devices continuous operation time from system and built-in power supply is at least 8 hours. Interval time before re-enable is at least 15 minutes.

Insulation resistance between case and isolated dc electric circuits in working conditions is not less than 5·1011 Ohm at dc voltage (500 ± 100 ) V.

 

Insulation between case and insulated from case dc electrical circuits ( all interconnected clamps) can withstand for 1 min test voltage of 0.5 kV, AC frequency 50 Hz in working condition , and between plug and case - 1.5 kV.

Resistance of each calibrated cables used in resistance measurement is from 0.0012 to 0.0015 Ohm.

Resistance of each calibrated cables, used for ratiometers and bridges verification is from 0.027 to 0.033 Ohm.

Resistance error (0.6 ; 1.6; 5 ; 15; 16.2 ; 25 Ohm) for simulation of   trunk pyrometric millivoltmeters is not more than ± 0.1 Ohm.

Dimensions are not more than 250x390x190 mm. Bridge p4833 weight is not more: without packaging - 8 kg; in transport container - 20kg . Total content of nonferrous metals , kg: aluminum D16A - 0.7; copper and copper-based alloys : copper wire MM - 0.3; bronze BrOF 6.5 -0.15-1 - 0.2, brass L63 - 1.02; brass LC59 -1 - 0.5.

  Technical characteristics :

R4833  can be used as: DC bridge; DC  Potentiometer; Resistance Box.       Temperature +10  +35 ° C;  Relative humidity  up to 80%;  Atmospheric pressure 84-106,7 kPa (630-800 mmHg);

This device also can named: P 4833, P- 4833  , P 4833  , R 4833  , R 4833  , R- 4833  , р 4833  ,  р  4833  , р - 4833  .   decade resistance box, resistance box, decade box, decade resistance, decade resistor box, shop, mera, etalon , resistance calibrators, calibrators.

Condition: 1.  used, from an old stock, has some scratches on the body;  2.  not tested; working condition is unknown ; 3.  Usually I send unit in  3-10 business days  after receiving payment – this time I need for unit testing procedure and preparing reliable packaging.

        Photos

If necessary we can take photos of a device from various angles.

      Technical Documentation

In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me.  I will look through the technical documentation for the device and I will be happy to consult you.

Also I may speak directly with the manufacturer and find out more specific information about this product.

If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.

On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.

In addition, translation of technical documentation into the customer’s language may be discussed.

             Delivery set

On delivering the device will be completely ready for use.

There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.

            Packaging

Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.

If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.

A special handle will be made for ease of transportation.

Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.

         Discount (from-10% to -90%)

I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty.

If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know.

I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then I guarantee to sell you a unit at that cheaper price with additional 10% discount.

 

        Shipping details:

Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.

I send goods via AirMailpost.

App. delivery time :

Europe – 7-15 days;

USA, Japan&others – 10-20 days (depends on a country).

I will ship in 5-10 business days after payment clearance.

The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.

With express delivery you will mostly receive your goods within 3-7 working days.

 

            Payment details:

I expect payment in 4 days after the auction ends.

I accept a PayPal payment as the safest way of payment (preferably).

If you do not have a PayPal account you can pay by wire transfer to my credit card.

Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment. 

(This will be an official purchase on eBay).

  Please, tell me if you cannot pay in time, we can always negotiate it. 

When purchasing a few items, you’ll save on shipping. 

 

         Return policy:

I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.

I will refund your costs or send you the other item, as you wish (after I receive the previous item ).

Please only serious bidders!

 

  • Condition: Used
  • Condition: Condition: 1. used, from an old stock, has some scratches on the body; 2. Not tested. Working condition is unknown.
  • Brand: P4833
  • Model: P4833

PicClick Insights - 100mkOhm-1000KOhm 0.1% P4833 Bridge impedance meter resistance standard box PicClick Exclusive

  •  Popularity - 7 watchers, 0.0 new watchers per day, 944 days for sale on eBay. Super high amount watching. 0 sold, 7 available.
  •  Best Price -
  •  Seller - 485+ items sold. 0% negative feedback. Great seller with very good positive feedback and over 50 ratings.